Pulse Oximeter CMS50D, 50DA

Pulse Oximeter CMS50D, 50DA
Item# cms50d
Regular price: $39.99
Sale price: $23.95
Availability: Usually ships the same business day

Finger Oximeter, Oxygen Meter, Oxygen Meters, Blood Oxygen Monitor, CMS-50D,CMS50D



The CMS50D Pulse Oximeter is a user-friendly measurement device for SpO2 and pulse rate. This portable oxygen meter uses standard removable batteries and does not require external wires or cables for power. Precise blood oxygen saturation and pulse rate results display on the color OLED screen for spot-checks or continuous monitoring. For a visual reference of test results, the monitor’s waveform and graph animations update with real-time data to provide a detailed view of vital activity.




FDA 510k Approved
Free case(soft zippered case) included
Free neck strap
Warranty: 1 year


Features

  • Integrated with SPO2 probe and processing display module.
  • Can measure SPO2 and PR accurately
  • SPO2 and PR display, PR waveform and bar graph display
  • Battery voltage low indication
  • Color OLED Display
  • Four levels adjustable brightness
  • Low power consumption; shut off automatically when no signal
  • Small volume(57(L) * 31(W) * 32(H) mm) light, convenient to carry
  • Can work more than 30 hours continuously


Technical Parameters

Display: 1.3' double Color OLED display, resolution 160*64
SPO2 Measuring Range: 35% - 100%
Pulse Ratio: 30bpm - 254bpm
Pulse Waveform Display: Bar graph display
Battery Indication: OLED Display
Power: 1.5V (AAA size) Alkali Batteries x2
Interference resistance capacity against ambient light and measurement performance at low perfusion
Adaptable Range: 2.6V - 3.6V
Working Current: <=25mA
SpO2 Resolution: 1%
Pulse Rate Resolution: 1bpm
Accuracy: : (±)2% (70%-99%), unspecified (<70%) for SPO2, (±)2BPM or(±)2% (select larger) for pulse ratio
Measurement at Low Perfusion: The values of SPO2 and pulse rate can be displayed properly when pulse saturation is at 0.4%
Resistance to Surrounding Light: Deviation is smaller than ±1% between value of Oxyhemoglobin measured in natural lighting indoor condition and present lighting sources and of that measured in dark room
Automatic Shutdown Function: The device will power off automatically within 5 seconds when there is no finger in the device. When working, the display direction can be changed by pressing the button shortly. There are six modes of direction. During working time, long press changes the brightness of the screen.